| Main system |
| PC communication |
USB2.0 High Speed |
| Line voltage |
100-240VAC, 50/60Hz, 1Amp |
| Power adapter |
24V @2.5A 60Watt |
| Size/weight |
411X321X165mm(W*D*H) / 4.4kg |
| Max output power |
15Watt |
| System |
| Cell cable |
1meter shielded type (Standard) |
| |
Working, reference, counter, |
| |
Working sense,Auxiliary V |
| Control |
DSP with FPGA |
| Calibration |
Automatic |
| Data acquisition |
2x16bit ADCs (500kHz)for voltage, current |
| ADC |
1x 16bit ADCs(250kHz) for auxiliary voltage |
| DAC |
2x16bit DAC(50MHz) for bias & scan |
| |
| Filter |
4ea (5Hz,1kHz,500kHz, 5MHz) |
| Scan rate |
0 – 200V/sec |
| 0-5000V/sec(fast scan) |
| Max. channel No. |
16 Channels via USB connection |
| Internal Data Memory |
295,000 points |
| Case |
5meter water proof |
| Power amplifier(CE) |
| Power |
12Watt (12V@1A) |
| Compliance voltage |
±12V |
| Maximum current |
±1A |
| Control speed selection |
4ea |
| bandwidth |
2MHz |
| Slew rate |
10V/usec |
| (Potentiostat mode(voltage control |
| - voltage control |
| Control voltage range |
±10V, ±1V, ±100mV |
| Voltage resolution |
16 bit per each range |
| Voltage accuracy |
±1mV±0.05% of setting |
| Max. scan range |
±10V vs. ref. E |
| - current measurement |
| Current ranges |
120ranges(auto/manual setting) |
| 1nA ~ 1A |
| (1nA & 10nA with gain) |
| Current resolution |
16 bit; |
| 30uA,3uA,300nA,30nA,3nA,300pA,, |
| 30pA,3pA, 300fA, 30fA, |
| Current accuracy |
±10pA±0.1% of range(gain x1) >100nA fs. |
| Galvanostat mode(current control) |
| - Current control |
| Control current range |
Max. ±1A |
| ± full scale depending on selected range |
| Current resolution |
16 bit; |
| 30uA,3uA,300nA,30nA,3nA,300pA,, |
| 30pA,3pA, 300fA, 30fA, |
| |
| Current accuracy |
±10pA±0.1% of range(gain x1) >100nA fs. |
| - Voltage measurement |
| Voltage ranges |
10V,1V,100mV |
| Voltage resolution |
16 bit; 0.3mV,30uV,3uV |
| Voltage accuracy |
±1mV±0.05% of reading |
| Electrometer |
| Max input voltage |
±10V |
| Input impedance |
2x1013ヘ||4.5pF |
| Bandwidth |
>22MHz |
| CMRR |
>114dB |
| |
|
| EIS(Internal FRA) for system |
| Frequency range |
10uHz ~ 1MHz |
| Frequency accuracy |
0.01% |
| Frequency resolution |
5000/decade |
| Amplitude |
0.1mV ~ 5V rms (Potentiostatic) |
| 0.1 ~ 70% f.s(Galvanostatic) |
| Mode |
Static EIS: |
| Potentiostatic, galvanostatic, pseudo-galvanostatic, OCP |
| Dynamic EIS: |
| Potentiodynamic, Galvanodynamic |
| Fixed frequency Impedance: |
| Potentiostatic, Galvanostatic, potentiodynamic, galvanodynamic |
| Multisine EIS: |
| Potentiostatic, Galvanostatic |
| Intermittent PEIS/GEIS |
| Interfaces for system |
| Auxiliary port |
|
| Auxiliary voltage inputs |
1 analog Input: ±10V |
| |
For measurement of WE vs. CE |
| Zero Resistance Ammeter |
100nA ~ 1A ranges |
| Software |
| Max steps per experiment |
1000 |
| Shutdown safety limits |
Voltage, current,AuxVetc |
| Max. sampling rate |
20kHz(50usec)-burst mode/500jHz(2usec) in fast sweep mode |
| Max. sampling time |
unlimited |
| Sampling condition |
Time, dv/dt, dI/dt etc. |
| PC requirement |
|
| Operating system |
WindowsXP SP3/7/8/10 |
| PC specification(minimum) |
Pentium4, RAM 1GB |
| Display |
1600x900 high color |
| USB |
High speed 2.0 |
| General |
| Dummy cell |
One external dummy cell included |